C8 Portable Colour Doppler Ultrasound System
Portable colour Doppler with colour Doppler enhancement, tissue harmonics, spatial compounding and panoramic imaging. 12.1-inch LCD, 4.5 kg.
- Brand: SonoStar
- Price: On request
- Probe frequency: Not applicable to the main unit - this is a console with two probe sockets; see the technical data for the optional probes
- Connection: Not applicable - the console has its own colour LCD and works independently, with no external display needed
- Charging: Dual power supply with a built-in high-capacity lithium battery; 2 hours on battery alone
- Category: Portable Ultrasound
Product overview
The C8 is a general-purpose portable colour Doppler system built around a 12.1-inch high-resolution colour LCD. Its imaging set covers 2D greyscale, colour Doppler enhancement, power Doppler, PHI pulse inversion tissue harmonic imaging with frequency compounding, spatial compounding, independent linear probe steering, speckle noise reduction, linear trapezoidal extension, convex extension, B/Color/PW triplex and panoramic imaging.
Measurement covers distance, area, circumference, volume, area ratio, distance ratio, angle, S/D velocity, time, heart rate and acceleration. On the obstetric side it handles fetal data for three or more fetuses, with fetal weight formulae, growth curve display and fetal echocardiography measurements including left ventricular function and left ventricular mass.
The system runs on a PC platform and weighs 4.5 kg net. A dual power supply with a built-in high-capacity lithium battery gives 2 hours of operation on battery alone, with the charge level shown on screen. Cold start takes 39 seconds, and two zero-insertion-force metal probe connectors are provided.
Technical specifications
Applications and intended use
| Item | Specification |
|---|---|
| System positioning | General-purpose colour Doppler system with panoramic imaging |
| Examination areas | Not listed separately in the source document; see the specialty measurement list under Measurement and analysis (abdomen, gynaecology, obstetrics, urinary tract, cardiac, paediatrics, small parts, vascular) |
Imaging functions
| Item | Specification |
|---|---|
| Basic imaging | 2D greyscale imaging, B-mode image enhancement, multi-beam parallel processing |
| Doppler imaging | Colour Doppler enhancement, power Doppler imaging |
| Advanced imaging | PHI pulse inversion tissue harmonic imaging with frequency compounding, spatial compounding, speckle noise reduction, independent linear probe steering, linear trapezoidal extension, convex extension, B/Color/PW triplex, panoramic imaging |
Measurement and analysis
| Item | Specification |
|---|---|
| General measurements | Distance, area, circumference, volume, area ratio, distance ratio, angle, S/D velocity, time, heart rate, acceleration |
| Obstetric measurements | Fetal data for three or more fetuses (OB1, OB2, OB3), with fetal weight formulae, growth curve display and fetal echocardiography including left ventricular function and left ventricular mass |
| Vascular flow measurements | Sample volume adjustable in at least 8 steps |
| Intima-media | Automatic measurement |
| Measurement data window | All measurement data windows can be moved |
| Custom annotations | Insert, edit and save |
General system functions
| Item | Specification |
|---|---|
| Platform | PC platform |
| Net weight | 4.5 kg |
| Monitor | 12.1-inch high-resolution colour LCD monitor |
| Power supply | Dual power supply with a built-in high-capacity lithium battery; 2 hours on battery alone, with the charge level shown on screen |
| Probe sockets | Zero-insertion-force metal connectors, 2 mutually compatible active sockets |
| Boot speed | Fast start and shutdown; cold start in 39 seconds |
| Main screen | Thumbnail view supported |
| Annotation input | Full-screen on-screen annotation; at least two Chinese input methods including Wubi |
| Patient data management | Built-in STATION patient data management workstation |
Probe specifications
| Item | Specification |
|---|---|
| Frequency range | Variable frequency, 2.0-10.0 MHz |
| Configurable probes | Convex, linear, endocavity, phased array, microconvex |
| Frequency steps | 5 frequency groups per probe, with variable fundamental and harmonic frequencies |
| Abdominal probe | 2.5-6.0 MHz |
| Superficial probe | 5.0-10.0 MHz |
| Endocavity probe | 5.0-9.0 MHz |
| Cardiac probe | 2.0-3.5 MHz |
| Combined B/D probes | Linear B/PW, convex B/PW, sector B/PW, phased array B/PW |
| Needle guidance | Optional needle guide bracket for the probe, with an adjustable needle line angle |
2D greyscale imaging parameters
| Item | Specification |
|---|---|
| Imaging modes | B, 2B, 4B, M, Color, PDI, PW, CW, anatomical M, B+C+PW triplex, B+PDI+PW triplex; single-window, dual-window real-time and quad-window display |
| Frame rate | Maximum 80 frames per second |
| Zoom | Real-time zoom (continuous) and frozen zoom (3x) |
| Transmit beam focusing | 4 foci |
| Receiving method | Multi-beam parallel signal processing |
| 2D image gain | Continuously adjustable |
| Scanning depth | 351 mm or more |
| Beamformer | Digital beamformer with digital full-depth dynamic focusing, dynamic variable aperture and dynamic apodisation; focus position adjustable throughout the imaging field |
| Cine review | 48 seconds of image review (phased array B-mode) |
| Presets | Optimised image conditions preset for each organ examined, reducing manual adjustment and combined adjustment during the examination |
| TGC segments | 8 |
| Pseudocolour maps | 7 |
| Sector scan angle | 4 steps, adjustable |
| Acoustic power | Visible and adjustable |
| Phased array B-mode cine capacity | 6898 frames or more at maximum |
| Color/PDI cine capacity | 4050 frames or more at maximum |
| Lithotripsy line | Supported |
| TEI index | Supported |
Spectral Doppler parameters
| Item | Specification |
|---|---|
| Transmit mode | Pulsed-wave Doppler (PW) and continuous-wave Doppler (CW) |
| PW range | 0-7.5 m/s |
| Doppler frequency | PW frequency adjustable |
| Maximum measured velocity | 7.5 m/s for forward or reverse flow |
| Automatic envelope | Doppler automatic envelope measurement and calculation |
| Sample volume width and position | Width 1-8 mm |
| Display control | Inverted display (left/right, up/down) |
| Automatic measurement | Real-time PW automatic measurement |
| Scale | 16 steps or more; PRF adjustable from 0.7-9.3 kHz |
| Cine review | Automatic cine playback |
Colour Doppler parameters
| Item | Specification |
|---|---|
| Doppler gain | Continuously adjustable |
| Colour enhancement | Supported |
| Dual display | Side-by-side B and COLOR display on the same screen |
| Baseline adjustment | Plus or minus 15 levels in colour mode |
Input, output and connectivity
| Item | Specification |
|---|---|
| Input signals | Digital signal interface provided |
| Output signals | VGA, S-VIDEO, USB, audio, network |
| Data interfaces | VGA, printer, network, S-VIDEO, foot switch |
| DICOM | DICOM 3.0 interface component for medical digital imaging and communication |
| Real-time network transfer | User data can be sent to a server in real time |
Image management and storage
| Item | Specification |
|---|---|
| Hard disk | 500 GB |
| Image management and recording device | Provided |
| Archiving and patient records | Storage, management and playback of static and dynamic patient images on the host unit |
Standard configuration and options
| Item | Specification |
|---|---|
| Standard configuration | Main unit, convex probe, linear probe |
| Optional items | Phased array probe, endocavity probe, microconvex probe, trolley, printer, external image and report workstation |
| Optional probe range | Phased array, endocavity, microconvex, convex, linear |
Specifications updated 2026-11-02
Typical applications
The application scenarios on this page describe the device based on its technical data and configuration. The actual scope of application is the one stated in the product registration certificate. Follow your institution's procedures and the instructions for use.
| Setting / department | Typical use | Configuration note |
|---|---|---|
| Emergency / ICU | Bedside examination of abdomen, heart, pleural and peritoneal fluid | Console with its own colour LCD, 4.5 kg |
| Obstetrics and gynaecology / urology | Gynaecological, obstetric and urinary tract examinations | Convex and endocavity probes optional |
| Cardiovascular / small parts | Cardiac, peripheral vascular, superficial tissue and small organ examination | Phased array and high-frequency linear probes optional |
| Primary care / health screening | Routine whole-body ultrasound | Two probe sockets, configured as needed |
Usage and selection notes
The C8 is a general-purpose portable colour Doppler system with panoramic imaging.
The actual scope of application is the one stated in the product registration certificate. Please confirm the model and configuration with our product department.
For contraindications and precautions, refer to the instructions for use. The device must be operated by a licensed physician with the relevant qualifications.
The technical data on this page is taken from the product technical documentation; where it has been updated, the latest version applies. The listed departments and application scenarios describe the device based on its technical data, and the actual scope of application is the one stated in the product registration certificate. This page makes no claim about clinical outcome and does not constitute clinical guidance.
Related products
Need a quote or a sample for evaluation?
Tell us how you plan to use the system and our sales team will reply within one business day.
Get a quote