Product Details

C5T Colour Doppler Ultrasound System

C5T

C5T trolley colour Doppler: 20-inch screen, 64 signal channels. Modes B, B/M, Color, PDI and PW; probes cover convex, linear and phased array.

  • Brand: SonoStar
  • Price: On request
  • Probe frequency: Complete system with two probe connectors; a range of probes is available (see specifications)
  • Connection: Self-contained colour LCD; works standalone, no external display needed
  • Charging: Main unit battery, about 2 hours of operation
  • Category: Trolley Ultrasound
Request a quote

Product overview

The C5T is a trolley colour Doppler ultrasound system built around a 20-inch screen and 64 signal processing channels. Imaging modes are B, B/M, Color, PDI and PW. Gain runs from 30 to 105 dB, noise reduction has five settings and dynamic range has eight.

Probe coverage is broad: convex, linear, high-frequency linear, phased array, microconvex, endocavity and rectal biplane, each with its own frequency band and scanning depth. Two probe connectors are fitted. Needle guidance covers both in-plane and out-of-plane lines, with automatic vessel measurement.

Images are stored on a 120 GB hard disk as JPG, AVI or DICOM, and print on most printers. The unit runs Windows and can connect over wired or wireless networks, transferring images and information through its DICOM and Worklist functions; remote consultation software can be installed on the main unit. The main unit battery runs for about 2 hours, and the trolley column adjusts from 770 mm to 1070 mm.

Technical specifications

Specifications

ItemData
Probe typesConvex, linear, phased array, microconvex, endocavity, rectal
Imaging modesB, B/M, Color, PDI, PW
Screen size20 inches
Channels64
Gain30-105 dB
Noise reduction0 / 1 / 2 / 3 / 4
Dynamic range40 / 50 / 60 / 70 / 80 / 90 / 100 / 110
Probe connectors2
Probe frequencyConvex 3.5-5.0 MHz; linear 7.5-10.0 MHz; high-frequency linear 10.0-14.0 MHz; phased array 2.2-3.6 MHz; microconvex 3.5-5.0 MHz; endocavity 6.5-8.0 MHz; rectal biplane (convex) 6.5-8.0 MHz; rectal biplane (linear) 7.5-10.0 MHz
Scanning depthConvex 90 / 160 / 220 / 305 mm; linear 20 / 40 / 60 / 100 mm; high-frequency linear 20 / 30 / 40 / 55 mm; phased array 40-100 mm; microconvex 90 / 130 / 160 / 200 mm; endocavity 40 / 60 / 80 / 100 mm; rectal biplane (convex) 40 / 60 / 80 / 100 mm; rectal biplane (linear) 20 / 40 / 60 / 100 mm
Scan angle and widthConvex 60 degrees; linear 40 mm; high-frequency linear 25 mm; phased array 80 degrees; microconvex 88 degrees; endocavity 149 degrees; rectal biplane (convex) 149 degrees; rectal biplane (linear) 40 mm
Needle guidanceIn-plane needle guideline; out-of-plane needle guidance with automatic vessel measurement
Image adjustmentGrey-scale gain, segmented TGC gain, dynamic range, focus, depth, pulse inversion harmonic, noise reduction, colour gain, colour box size, PRF
Cine playbackManual and automatic playback; frame count selectable at 100 / 200 / 500 / 1000
MeasurementsDistance, area, perimeter, heart rate, obstetric and others
Frame rate18 frames per second
Operating systemWindows
Image storageJPG, AVI and DICOM; 120 GB hard disk
PrintingMost printers supported
Network transferWired or wireless; images and information transferred through the built-in DICOM and Worklist functions or other software
Remote consultationRemote consultation software can be installed on the main unit
BatteryMain unit battery, about 2 hours of operation
Trolley dimensionsHeight adjustable 770-1070 mm; keyboard surface 440 mm x 265 mm; printer surface 480 mm x 480 mm
Packing dimensions690 mm x 555 mm x 235 mm
WeightNet 20 kg, gross 25 kg
Standard configurationMain unit x1, convex probe x1
OptionalLinear, phased array, microconvex, endocavity and rectal probes; probe needle guide; tablet; trolley; external battery; remote consultation system

Specifications updated 2026-11-01

Typical applications

The application scenarios on this page describe the device based on its technical data and configuration. The actual scope of application is the one stated in the product registration certificate. Follow your institution's procedures and the instructions for use.

Setting / departmentTypical useConfiguration note
Emergency / ICUBedside scanning of the abdomen, the heart and pleural or peritoneal fluidSelf-contained unit with a colour LCD
Obstetrics / gynaecology / urologyGynaecological, obstetric and urinary tract examinationsConvex and endocavity probes available
Cardiology / small partsCardiac, peripheral vascular, superficial tissue and small organ examinationsPhased array and high-frequency linear probes available
Primary care / health screeningGeneral whole-body ultrasoundSeveral probe connectors, configured to need

Usage and selection notes

The C5T is a complete-system product and belongs to a different product line from the wireless probes.

A number of probe types can be fitted, so the configuration supplied is the one on the order sheet. Please confirm the selection with our product department.

For contraindications and precautions, refer to the instructions for use. The device must be operated by a licensed physician with the relevant qualifications.

The technical data on this page is taken from the product technical documentation; where it has been updated, the latest version applies. The listed departments and application scenarios describe the device based on its technical data, and the actual scope of application is the one stated in the product registration certificate. This page makes no claim about clinical outcome and does not constitute clinical guidance.

Related

Related products

Need a quote or a sample for evaluation?

Tell us how you plan to use the system and our sales team will reply within one business day.

Get a quote
Home Call
Call +86 13434822215 (Mr. Zhong)